第4期刘文胜,等:600MW亚临界锅炉30%额定负荷深度调峰试验研究65
Experimental Study on30%Rated Depth Peak-load
for a600MW Sub-critical Boiler
LIU Wensheng,LYU Hongkun,CAI Jiecong,WANG Maogui
(State Grid Zhejiang Electric Power Research Institute,Hangzhou310014,China)
Abstract:The operating capability of a boiler with a sub-critical600MW unit is studied when the depth is raised to30%rated.The results show that the boiler combustion is stable at low load without equipment transformation and no combustion-supporting,the main and auxiliary system of boiler are normal and safe,the boiler meets the ultra-low emission requirements,and the boiler basically realizes the goal of depth peak-load to30%rated load in a static manner・However,the boiler also has problems such as weak signal of secondary air flow measuring device,low temperature and large ammonia injection of SCR denitrification system,and low efficiency of boiler.This is a problem that needs to be solved to further improve the boiler depth peak-load ability.
Key words:depth peak-load;low load steady combustion;NO X emission;boiler efficiency;measuring device