Materials: Grey Thermoplastic UL Flammability: UL 94VO
Horsepower Rating of Switch:
3PH V 240480600HP 51015
Agency Information:
UL (see table below)
CSA Certified, C22.2 No. 39, Class 6225-01, File 47235IEC (see table below)
Shipping Weight:Approx. 335g (.74 lb.)Carton Quantity: 1
Physical Characteristics:
•Small size matches 45mm IEC starter width.
•Fits #8-18 AWG stranded wire, #10-18 AWG solid wire.•3-pole version.
•Handle and shaft required for through-the-door operation. (See ordering information on page 2).Product Features:
•“Open” fuse indication lights.
•Finger-safe terminals. (Qualified as IP2O per IEC529)•Cam action handle for easy module removal.
•35mm DIN-rail or screw panel mounting (#8 screw, 1 1⁄4˝ long).•Dead front construction. No exposed contacts for added safety.•Option for remote “open fuse” status indication feature available (reduces downtime).
•Offered with Class CC rejection clips or European 10mm x 38mm clips to meet global needs.
•Wire ready: Saves time as terminals are ready to accept wires.
OPTIMA ™
OPM-1038
Overcurrent Protection Module - Fuseholder and Switch Series
Disconnect Switch for 13⁄32˝ x 1 1⁄2˝ (10mm x 38mm) Fuses
Catalog SC Remote Open UL Information Number Electrical Rating Rating Clips Fuse Indication
Std.File Guide IEC
OPM-1038SW
30A, 600Vac UL/CSA *
Non-rejection No
Recognized (Max. 3 Watts per fuse)10x 38mm or
32A, 660Vac IEC
13/32” x 1-1/2”
UL 508
E161278NLRV2IEC 947-3
OPM-1038RSW 30A, 600Vac UL/CSA 100kA Rejection No Listed UL 508E161278NLRV
OPM-1038SWC
30A, 600V UL/CSA
*
Non-rejection Yes
Recognized (Max. 3 Watts per fuse)10x 38mm or
32A, 660Vac IEC
13/32” x 1-1/2”
UL 508
E161278NLRV2
IEC 947-3
OPM-1038RSWC 30A, 600Vac UL/CSA 100kA
Rejection Yes
Listed Class CC
UL 508
E161278NLRV
*Rating varies depending on fuse used in module, 100kA maximum..
Recommended Fuse Types:Class CC Midget (non-rejection)LP-CC KTK KTK-R FNM FNQ-R FNQ Spare Fuseholder: Part No. 5TPH
O P M -1038S W
Series
Fuse Type
Communication
C - Communication
Feature
Blank - 10 x 38mm
or 13/32” x 1-1/2”R - Class CC
Catalog Symbol:
C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o m
Ordering Information for External Handle*:
OPTIMA Module + CDRKBS12 + Handle + Shaft
= Complete Disconnect Switch (without fuses)1. Order Cooper Bussmann part number CDRKBS12.2. Select the appropriate handle style (Selector or Pistol).3. Select the shaft corresponding to the handle type and mounting depth required.
*All switchable OPM-1038 modules come standard with a small black handle Cooper
Bussmann part number CDRKBS12 must be ordered for all through-the-door applications.
1038Dimensional Data
Extended Shafts - Shaft Dimension (K 6x6mm )For Handle Mounting Shaft Catalog Type
Depth **Length Number 4.2 - 5.0˝ 3.3˝ (85mm)BDS85S 5.0 - 5.8˝ 4.1˝ (105mm)BDS105S 5.6 - 6.4˝ 4.7˝ (120mm)BDS120S Selector
6.0 - 6.7˝ 5.1˝ (130mm)BDS130S
7.1 -
8.7˝7.1˝ (180mm)BDS180S 10.7 - 11.5˝
9.8˝ (250mm)BDS250S 13.8 - 14.6˝13.0˝ (330mm)BDS330S 6.2 - 6.7˝ 5.9˝ (150mm)BDS1507.0 - 7.5˝ 6.7˝ (170mm)BDS170Pistol
10.7 - 11.3˝10.4˝ (265mm)BDS26516.0 - 16.6˝15.8˝ (400mm)BDS40020.0 - 20.5˝19.7˝ (500mm)BDS500
**Mounting depth is the distance from the outside of the door to the disconnect switch. Shaft can be cut to desired length.
0.57∑ (± 0.03)Selector Handles - for use with shafts K 0.24˝ x 0.24˝ (K 6x6mm)NEMA IEC Color Defeatable Padlockable Weight Catalog type type
(lbs)number All marked both O/l & Off/On 1IP54Black ——0.09CBDH1S 1IP54Red/Yel ——0.09CBDH2S 1IP54Black —Yes 0.12CBDH15S 1IP54Red/Yel —Yes 0.12CBDH16S 1,3R,12IP65Black —Yes 0.16CBDH3S 1,3R,12IP65Red/Yel —Yes 0.16CBDH4S 1,3R,12IP65Black Yes Yes 0.16CBDH5S 1,3R,12
IP65
Red/Yel
Yes
Yes
0.16
CBDH6S
Pistol Handles - for use with shafts K 0.24˝ x 0.24˝ (K 6x6mm)NEMA IEC Color Marking Length Defeatable Padlockable Weight Catalog type type inches/mm (lbs)number All marked both O/l & Off/On
1,3R,12
IP65 Black O/l & Off/On 1.8/45 Yes Yes 0.28BDH561,3R,12IP65 Red/Yel O/l & Off/On 1.8/45 Yes Yes 0.28 BDH571,3R,12 IP65 Black O/l & Off/On 2.6/65 Yes Yes 0.29 BDH581,3R,12 IP65 Red/Yel O/l & Off/On 2.6/65 Yes Yes 0.29BDH591,3R,12,4,4X IP66 Black O/l & Off/On 2.6/65 Yes Yes 0.29 CDHXB65L61,3R,12,4,4X IP66 Red/Yel O/l & Off/On
2.6/65 Yes Yes 0.29 CDHXY65L6
C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o m
Status Output Specifications:
*Minimum operating voltage: 460Vac, 3-phase *Maximum operating voltage: 620Vac, 3-phase
Status output maximum conducting current: 40mA Status output maximum on resistance: 35 ohms @ 40mA
Status output typical off resistance: >10 Mohm Status output maximum turn-on and turn-off delay: 850 milli-second
Status Output Interface Specifications:
Rated Voltage: Recommended 5-35Vdc, 300Vac max.Rated Current: 40mA max.Wire Size: #28-14 AWG Torque: 2.25 lb. in.
Open Fuse Indicator Status Output Description:The open fuse indicator status output acts very much like an on/off switch. With all three fuses in place and operating properly, this status output has a high resistance value of greater than ten mega-ohms. When one or more of the fuses are open, the status output becomes turned-on with a resistance value less than 35 ohms. This status output withstands voltage (ac or dc) up to 35V at off-state and conducts current u
p to 40 milli-amps at on-state.Applying voltage and current exceeding these limits will result in damage to the components inside this status
output device permanently. There is some time-delay when the status output changes on/off state. The open fuse communications or status output device includes optical isolators within the unit.
Communications output states:Fuse Good NO - High Resistance, >10 megohms Opened Fuse NC - Low Resistance, < 35 ohms
OPEN FUSE INDICATION
Note: Operating this device beyond the above limits will
cause permanent damage to the components on the board.For applications requiring status output below a system voltage of 460V, contact Bussmann.
The examples shown below illustrate typical interface to
Programmable Logic Controllers.
STATUS OUTPUT
TTL Digital Input
PC / PLC
Vcc (5V to 35V)
Pull up Resistor (> 1K)
EXAMPLE 1: DIRECT INTERFACE TO PC/PLC
PC / PLC EXAMPLE 2: INTERFACE TO PC / PLC WITH OPTICAL ISOLATION
Current-Limiting Resistor
Optical Isolator
TTL Digital Input
Vcc (5V to 35V)
ISOLATED AC OR DC POWER SOURCE
STATUS OUTPUT
Pull up Resistor (> 1K)
Note: When energized (switch in the “on” position), a low load terminal voltage will
be present when fuses are open or when pullout module is removed. The leakage current is limited to .5mA maximum .
Example of Output Voltage with three open fuses or pullout module removed.Catalog Number OPM-1038RSW, OPM-1038SW OPM-1038-RSWC, OPM-1038SWC Types of Indication Standard Communication System Voltage Load Terminal Voltage (1L1-3L2-5L3)(2T1-4T2-6T3)125Vdc *
12Vdc *31Vdc *480Vac, 3-phase 26Vac 56Vac 600Vac, 3-phase 33Vac 88Vac
There is no voltage at the load terminals (2T1-4T2-6T3) on the switch version (SW suffix) when the switch is in the “off” position.
*The communication device requires a minimum circuit voltage (1L1-3L2-5L3) of 460V for the status indicating device to operate. Below 460V , but above 120V , the indicator lights will luminate, but there will not be any communication status output.
The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical informa-tion that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o m
版权声明:本站内容均来自互联网,仅供演示用,请勿用于商业和其他非法用途。如果侵犯了您的权益请与我们联系QQ:729038198,我们将在24小时内删除。